Use Of Cusp-Overlapping Projection In TAVR Reduces Rate Of Permanent Pacemaker Implantation: JACC
- byDoctor News Daily Team
- 06 August, 2025
- 0 Comments
- 0 Mins

Spain: A novel cusp-overlapping projection (COP) technique was shown to significantly reduce the rate of permanent pacemaker implantation (PPMI) in self-expanding (SE) transcatheter heart valve (THV) implantation versus the classical implantation technique, states a recent study. Also, both the techniques were found to have similar rates of complications.
"The findings imply that the COP implantation technique is a safe and feasible modification to the transcatheter aortic valve replacement (TAVR) protocol, " Isaac Pascual, Research Institute of the Principado de Asturias, Oviedo, Spain, and colleagues wrote in their study published in the journal JACC: Cardiovascular Interventions. "This is the first study to systematically evaluate this approach for SE THVs in different populations."
The COP technique was shown to have a potential benefit of an optimized implantation depth to reduce the PPMI rate. However, not many studies have compared clinical outcomes with those achieved using the standard technique.
Considering the above, Dr. Pascual and colleagues conducted the study with an aim to determine if modifying the classical implantation technique for SE transcatheter aortic valve replacement to a novel COP technique leads to a higher implantation depth (ID) and a subsequent reduction in the rates of PPMI.
The study included 444 consequent patients beginning in February 2015. Because of the observational nature of the study propensity score matching was used to control baseline characteristics. A total of 161 pairs of patients were analyzed. Three methods were used to measure ID (noncoronary cusp [NCC] to the THV, mean of the NCC and the left coronary cusp [LCC] to the THV, and the deepest edge from the LCC and the NCC to the THV).
Based on the study, the authors gave the following findings:
ID was significantly higher in COP cases when measuring from the NCC (4.2 mm vs 5.3 mm) and the mean from the NCC and the LCC (5.3 mm vs 5.9 mm), but not from the deepest edge.
The PPMI rate was lower in the COP group: 19 (11.8%) vs 35 (21.7%) (relative risk: 0.54).
The authors conclude, "COP technique significantly reduces PPMI in SE THV implantation compared with the classical implantation technique, with similar rates of complications."
Reference:
The study titled, "Permanent Pacemaker Reduction Using Cusp-Overlapping Projection in TAVR: A Propensity Score Analysis," was published in the journal JACC: Cardiovascular Interventions.
DOI: https://doi.org/10.1016/j.jcin.2021.10.002
Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at
admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our
Terms of Use,
Privacy Policy, and
Advertisement Policy.
For further details, please review our
Full Disclaimer.
Recent News
Chennai: Fortis Healthcare Opens 250-Bedded 2nd Mu...
- 06 July, 2025
New Lab-On-A-Chip, Cheaper, Faster, On The Spot Di...
- 06 July, 2025
Steroids And Plasma Exchange Do Not Alter Prognosi...
- 14 February, 2020
Daily Newsletter
Get all the top stories from Blogs to keep track.
0 Comments
Post a comment
No comments yet. Be the first to comment!