Two Narrow-Diameter Titanium-Zirconium Implants With Stud-Attachments Tied To Highly Satisfactory Outcome In Mandible: Study
- byDoctor News Daily Team
- 06 August, 2025
- 0 Comments
- 0 Mins

Two narrow-diameter titanium-zirconium implants with stud-attachments tied to highly satisfactory outcome in mandible, suggests a study published in the Clinical oral implants research.
To evaluate the survival rates and marginal bone loss of narrow-diameter titanium-zirconium implants supporting complete maxillary and mandibular overdentures up to 3 years after loading. Ten completely edentulous patients who were dissatisfied with their complete dentures were enrolled. Two narrow-diameter implants were placed in the canine region of the maxilla and mandible. After second-stage surgery, implant-supported overdentures (palatal-free) attached by parallel alignable stud-attachments were placed. Patients were followed periodically for up to 36 months. Standardized radiographs were taken at baseline, 12 and 36 months to analyze mean marginal bone level changes around the implants.
Results: The Kaplan-Meier survival rates were 100% for mandibular and 68.0% (SE ± 10.9%) for maxillary implants at 36 months (p = .008). Six maxillary implants failed after loading; no mandibular implants were lost. Five implants failed due to loss of osseointegration. One implant fractured. The mean marginal bone level changes around the analyzed implants (n = 28, 9 patients) were -0.71 ± 0.82 mm in the mandible and -2.08 ± 1.52 mm in the maxilla at the 36-month follow-up. The difference in marginal bone level changes between the maxilla and mandible was significant (p = .019) at the 12- and 36-month follow-ups. Two narrow-diameter titanium-zirconium implants with stud-attachments showed a highly satisfactory outcome in the mandible. The maxillary implants showed a high failure rate and significantly more bone loss over time than the mandibular implants. The minimal concept of two implants and an overdenture should be limited to the edentulous mandible.
Reference:
Kern JS, Salin E, Elvers D, Rittich A, Tuna T, Hölzle F, Wolfart S. Maxillary and mandibular overdentures retained by two unsplinted narrow-diameter titanium-zirconium implants - A clinical pilot study. Clin Oral Implants Res. 2024 Jun 1. doi: 10.1111/clr.14303. Epub ahead of print. PMID: 38822688.
Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at
admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our
Terms of Use,
Privacy Policy, and
Advertisement Policy.
For further details, please review our
Full Disclaimer.
Recent News
Chennai: Fortis Healthcare Opens 250-Bedded 2nd Mu...
- 06 July, 2025
New Lab-On-A-Chip, Cheaper, Faster, On The Spot Di...
- 06 July, 2025
Steroids And Plasma Exchange Do Not Alter Prognosi...
- 14 February, 2020
Daily Newsletter
Get all the top stories from Blogs to keep track.
0 Comments
Post a comment
No comments yet. Be the first to comment!