For unstable scaphoid fractures failure rates are as high as 92% especially with an initial displacement exceeding one millimeter, which is why surgical treatment became the gold standard.
The primary method employed worldwide for the treatment of scaphoid fractures is screw fixation. However, in unstable and comminuted fractures, percutaneous fixation could produce complications due to technical challenges, such as improper axis positioning, inaccurate screw length measurement, intra-articular screw penetration, and impingement.
Alternative open approaches for the surgical management of scaphoid fractures have been proposed, and in recent years, a new specific volar locking plate for the treatment of scaphoid fractures has been developed.
L. Marzella et al conducted a study to verify the effectiveness of the volar plate in the treatment of comminuted scaphoid fractures and the necessity for plate removal when consolidation has occurred. It has been published in ‘European Journal of Orthopaedic Surgery & Traumatology.’
The authors present results and consideration about a case series of 44 comminuted scaphoid fractures treated with volar locking and angular stability plate. A retrospective study was conducted involving all patients, consisting of continuous clinical and radiographic assessments, functional evaluations (using QuickDASH and MHQ), and patient satisfaction surveys. The Kolmogorov–Smirnov test was used to determine the normal distribution of data. A paired t test was performed to evaluate the difference between the preoperative and postoperative values. A P-value of
Key findings of the study were:
• All fractures had traumatic causes, with the majority resulting from car accidents.
• All patients achieved clinical and radiographic recovery. However, the plate can impinge with nearby structures and should be removed once the fracture is consolidated.
• After plate removal, further improvement in range of motion was observed.
The authors concluded that - “The plate and screws system is a viable and appropriate method of osteosynthesis in the treatment of unstable and comminuted recent fractures occurring in the middle third of the carpal scaphoid.”
Further reading:
Volar locking and angular stability plate for treatment of comminuted scaphoid fractures: a case series of 44 cases.L. Marzella et al European Journal of Orthopaedic Surgery & Traumatology https://doi.org/10.1007/s00590-024-04095-2
Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at
admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our
Terms of Use,
Privacy Policy, and
Advertisement Policy.
For further details, please review our
Full Disclaimer.

Recent News
Normal-Tension Glaucoma Closely Associated With Co...
- 10 October, 2022
Air Pollution Tied To Increased Risk Of Premature...
- 24 May, 2023
NEET PG 2024: NBE Opens Pre-Final Edit Window
- 30 May, 2024
NMC Mulls Over Removal Of Upper Age Cap In MBBS En...
- 30 November, 2021

Daily Newsletter
Get all the top stories from Blogs to keep track.
0 Comments
Post a comment
No comments yet. Be the first to comment!