Paclitaxel-Coated Balloon Effective For Managing Coronary In-Stent Restenosis Among Patients Undergoing PCI: JAMA
- byDoctor News Daily Team
- 18 February, 2025
- 0 Comments
- 0 Mins

USA: A multicenter randomized trial of 600 patients (AGENT IDE) designed to support US regulatory approval, has shown treatment with a paclitaxel-coated balloon to be an effective treatment strategy for managing coronary in-stent restenosis.
The study, published in the Journal of the American Medical Association (JAMA), showed a significantly lower target lesion failure in the paclitaxel-coated balloon group (17.9%) versus the uncoated balloon group (28.6%). Additionally, target vessel myocardial infarction (MI) and ischemia-driven target lesion revascularization were also lower after treatment with a paclitaxel-coated balloon.
"The trial is the largest randomized clinical trial to date examining the safety and efficacy of a drug-coated balloon in coronary in-stent restenosis patients, and the first trial of coronary drug-coated balloons to be conducted in the United States," the researchers wrote.
Drug-coated balloons were designed for administering antiproliferative agents to coronary lesions without using metallic stents. They developed an alternative treatment for coronary artery disease, specifically for in-stent restenosis, where the introduction of additional layers of stent that further decrease lumen area may be undesirable. However, none have been previously evaluated or approved for use in coronary circulation in the United States.
Against the above background, Robert W. Yeh, Beth Israel Deaconess Medical Center, Boston, Massachusetts, and colleagues evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention (PCI).
For this purpose, the researchers performed a multicenter randomized clinical trial, AGENT IDE, enrolling 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the US between 2021 and 2022. One-year clinical follow-up completed on October 2, 2023. Among 600 randomized patients (mean age, 68 years; 26.2% females), 574 completed 1-year follow-up.
Participants were randomized in a 2:1 ratio to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon.
The primary endpoint of 1-year target lesion failure (defined as the composite of ischemia-driven target lesion revascularization, cardiac death, or target vessel–related MI) was tested for superiority.
The researchers reported the following findings:
The primary endpoint at one year occurred in 17.9% of the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59).
Target lesion revascularization (13.0% versus 24.7%; HR, 0.50) and target vessel–related myocardial infarction (5.8% versus 11.1%; HR, 0.51) occurred less frequently among patients treated with a paclitaxel-coated balloon.
The rate of cardiac death was 2.9% versus 1.6% (HR, 1.75) in the coated vs uncoated balloon groups, respectively.
In conclusion, a paclitaxel-coated balloon was superior to an uncoated balloon concerning the composite endpoint of target lesion failure in patients undergoing coronary angioplasty for in-stent restenosis.
"The findings showed that paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis," the investigators concluded.
Reference:
Yeh RW, Shlofmitz R, Moses J, et al. Paclitaxel-Coated Balloon vs Uncoated Balloon for Coronary In-Stent Restenosis: The AGENT IDE Randomized Clinical Trial. JAMA. Published online March 09, 2024. doi:10.1001/jama.2024.1361
Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at
admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our
Terms of Use,
Privacy Policy, and
Advertisement Policy.
For further details, please review our
Full Disclaimer.

Recent News
Normal-Tension Glaucoma Closely Associated With Co...
- 10 October, 2022
Air Pollution Tied To Increased Risk Of Premature...
- 24 May, 2023

Daily Newsletter
Get all the top stories from Blogs to keep track.
0 Comments
Post a comment
No comments yet. Be the first to comment!