August 19, 2025

Get In Touch

Infrared Sensor Technology May Reduce Clinical Time And Number Of Visits In Mounting Process Of Edentulous Casts

The conventional diagnostic mounting procedure in completely edentulous patients is time-consuming and increases the laboratory workload.

Infrared Sensor Technology May Reduce Clinical Time And the Number Of Visits In the Mounting Process Of Edentulous Casts suggests a recent study published in the Journal of Prosthetic Dentistry.
The conventional diagnostic mounting procedure in completely edentulous patients is time-consuming and increases the laboratory workload. Alternatives like optical scanners and jaw tracking devices have been documented but have their own shortcomings.

The purpose of this pilot clinical study was to assess the suitability of an infrared sensor scan device in procuring the diagnostic data parameters for completely edentulous patients.
Twelve completely edentulous participants were enrolled in the study. For each, the distance between the arches was measured by 2 clinical techniques at 3 common reference points, M1, M2, M3, for the maxillary arch and m1, m2, m3 for the mandibular arch. The control group measurements were recorded by using a standard diagnostic mounting procedure on a semi-adjustable articulator, and the experimental group measurements were recorded by using an infrared sensor scan device. To convert the analog infrared sensor output into digital data, the Arduino ADC software program was used. The data from both study groups were statistically compared by using the independent t test (α=.05).

Results
No significant difference in variation was found between the mean measurements of the device and diagnostic mounting (P>.05).
The maximum variation recorded by the experimental device was 1.7 mm, whereas the minimum variation was 0.8 mm (mean 1.25 mm).
The use of precisely calibrated infrared sensors may be a cost-effective option for diagnostic mounting.
Reference:
Aryen Kaushik, Taranjeet Kaur, Shashidhara Hebbal Shadaksharappa, Pooja Rani, Shikha Sharma, Harsh Vardhan Sinha. A comparative evaluation of the diagnostic accuracy of an infrared sensor device with standard mounting procedure in completely edentulous patients: A pilot clinical study. Journal of Prosthetic Dentistry. Published:December 17, 2022. DOI:https://doi.org/10.1016/j.prosdent.2022.11.014

Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our Terms of Use, Privacy Policy, and Advertisement Policy.
For further details, please review our Full Disclaimer.

0 Comments

Post a comment

Please login to post a comment.

No comments yet. Be the first to comment!