No statistically significant difference in implant survival between immediately loaded two implant-supported overdenture retained with locator or bar attachments suggests a new study published in the Journal of Clinical Periodontology.

A study was done to evaluate the long-term survival, incidence of prosthetic/technical and biological complications and the oral-health-related quality of life in patients with an edentulous mandible who were fitted with overdentures on two immediately loaded implants in the symphyseal area.

Forty-six patients with edentulous mandibles received two immediately loaded implant-retained dentures with either two Locator attachments or egg-shaped bar attachments. Implant outcomes were recorded after a period of observation of 9 years and included prosthetic complications, modified gingiva index (mGI), modified plaque index (mPI), oral health impact profile (OHIP-G) and radiographic estimation of bone loss.
Results
In 2020/2021, 27 patients with 54 implants were still available for follow-up. In total, nine implants in six patients were lost. Survival was 89.1% in the bar group and 91.3% in the Locator group. Implant success was 84.6% in the Locator group and 76.9% in the bar group. The mPI values were significantly higher in the bar group than in the Locator group, whereas no difference was seen in the mGI values. During the observation period, 152 prosthetic complications occurred, but the OHIP-G score did not differ significantly.
There was no difference in implant survival between Locator or joint bar attachments over a 9-year observation period. Joint bar attachments were associated with slightly more complications, while patients in the Locator group were able to maintain better oral hygiene. The study was registered in the German Register of Clinical (Trials DRKS00004245).
Reference:
Kostunov, J., Menzel, R., Bermejo, J. L., Rammelsberg, P., Giannakopoulos, N. N., & Kappel, S. (2023). Immediate loading of dental implants in edentulous mandibles using Locator attachments or Dolder bars: A 9-year prospective randomized clinical study. Journal of Clinical Periodontology, 1–9. https://doi.org/10.1111/jcpe.13857
Keywords:
No, statistically, significant, difference, implant, survival, between, immediately, loaded, two, implant–supported, overdenture, retained, locator, bar attachments, Kostunov, J., Menzel, R., Bermejo, J. L., Rammelsberg, P., Giannakopoulos, N. N., & Kappel, S.

Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our Terms of Use, Privacy Policy, and Advertisement Policy.
For further details, please review our Full Disclaimer.

0 Comments

Post a comment

Please login to post a comment.

No comments yet. Be the first to comment!