June 23, 2025

Get In Touch



ICDs Fail To Improve Survival In Nonischemic Systolic HF Patients: Study

Implantable Cardioverter-Defibrillators (ICDs) is beneficial in Younger Nonischaemic Heart Failure (HF) patients, according to a recent study published in the Circulation.
The Danish Study to Assess the Efficacy of Implantable Cardioverter-Defibrillators (ICDs) in Patients with Non-ischemic Systolic Heart Failure on Mortality (DANISH) found that primary-prevention ICD implantation was not associated with an overall survival benefit in patients with non-ischemic systolic heart failure during a median follow-up of 5.6 years, though there was a beneficial effect on all-cause mortality in patients ≤70 years. This study presents an additional four years of follow-up data from DANISH.
In DANISH, 556 patients with non-ischemic systolic heart failure were randomized to receive an ICD and 560 to receive usual clinical care and followed until June 30, 2016. In this long-term follow-up study, patients were followed until May 18, 2020. Analyses were conducted for the overall population and according to age (≤70 and >70 years).
The Results of the study are:
During a median follow-up of 9.5 years (25th-75th percentile, 7.9-10.9 years), 208/556 patients (37%) in the ICD group and 226/560 patients (40%) in the control group died. Compared with the control group, the ICD group did not have significantly lower all-cause mortality (HR 0.89 [95%CI,0.74-1.08]; P=0.24). In patients ≤70 years (n=829), all-cause mortality was lower in the ICD group than the control group (117/389 [30%] vs 158/440 [36%]; HR 0.78 [95%CI,0.61-0.99]; P=0.04), whereas in patients >70 years (n=287), all-cause mortality was not significantly different between the ICD and control group (91/167 [54%] vs 68/120 [57%]; HR 0.92 [95%CI,0.67-1.28]; P=0.75). Cardiovascular death showed similar trends (overall, 147/556 [26%] vs 164/560 [29%], HR 0.87 [95%CI,0,70-1.09], P=0.20; ≤70 years, 87/389 [22%] vs 122/440 [28%], HR 0.75 [95%CI,0.57-0.98], P=0.04; >70 years, 60/167 [36%] vs 42/120 [35%], HR 0.97 [95%CI,0.65-1.45], P=0.91). The ICD group had a significantly lower incidence of sudden cardiovascular death in the overall population.
Thus, the researchers concluded that during a median follow-up of 9.5 years, ICD implantation did not provide an overall survival benefit in patients with non-ischemic systolic heart failure. In patients ≤70 years, ICD implantation was associated with a lower incidence of all-cause mortality, cardiovascular death, and sudden cardiovascular death.
Reference:
Long-term Follow-up of The Danish Study to Assess the Efficacy of ICDs in Patients with Non-ischemic Systolic Heart Failure on Mortality (DANISH) by Adelina Yafasova et al. published in the Circulation.
https://www.ahajournals.org/doi/10.1161/CIRCULATIONAHA.121.056072

Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our Terms of Use, Privacy Policy, and Advertisement Policy.
For further details, please review our Full Disclaimer.

0 Comments

Post a comment

Please login to post a comment.

No comments yet. Be the first to comment!