Anchor Suture Fixation For Treatment Of Inferior Patellar Pole Fractures Better Than Traditional Methods
- byDoctor News Daily Team
- 18 February, 2025
- 0 Comments
- 0 Mins

Anchor suture fixation for treatment of inferior patellar pole fractures better than traditional methods finds a new study by researchers.The findings of the study have been published in the journal Orthopaedic Surgery.
Jia Xie, Yu Fu et al conducted a retrospective study on treatment of inferior patellar pole fractures at the Second Hospital of Anhui Medical University and Hefei Cancer Hospital, Chinese Academy of Sciences, Hefei, China.
Patients with distal pole fractures of the patella have a disrupted extensor mechanism, which results in considerable functional disability. The ideal method should comply with three crucial demands: it should aid in reduction of the fracture, provide stable fixation and enable early rehabilitation.
Various methods have been introduced to fix distal patellar pole fractures, including tension band wiring, separate vertical wiring, the use of a basket plate, wiring through cannulated screws, and partial patellectomy, and each of these techniques has characteristic advantages and disadvantages.
The modified anterior tension band technique using Kirschner wire (K-wire) is one of the most common methods. Patients frequently complain of discomfort secondary to prominent hardware, leading to high rates of removal of hardware (ROH). Thus, revision surgery with K-wire removal becomes necessary in up to 65% of cases.
A novel technique that employs the application of two or three anchors to the patella and reattachment of the distal fragments together with the patellar tendon.
This study aims to quantify clinical and postoperative functional outcomes and to identify postoperative complications in a cohort of patients who were treated with non-absorbable braided suture fixation for distal pole fractures of the patella. These patients were then compared to a control group of patients who were treated for distal pole fractures of the patella using Kirschner wire.
Inclusion criteria: (i) diagnosed as distal pole avulsion fractures of the patella on CT or X-rays; (ii) accepted anchor and Krackow-"8" suture fixation (AS) and K-wire fixation; (iii) complete follow-up data; and (iv) retrospective study. Excluded criteria: (i) patients with other types of patella fractures; (ii) open fractures; (iii) no history of surgery in the affected limb; and (iv) patients who were unable to understand the items on the questionnaire.
Twenty-eight eligible patients with distal pole patella fractures were reviewed retrospectively. The anchor and Krackow-"8" suture fixation (AS group) was applied in 10 patients and 18 patients underwent K-wire fixation (K-wire group). The average age of patients was 46.000 +/-19.476 years in the AS group and 47.556 +/- 15.704 years in the K-wire group, with comparable demographic characteristics. All patients underwent regular follow-up the operative data and postoperative functional and clinical outcomes were recorded. Complications were recorded by clinical and radiographic assessment. Bostman patellar fracture functional score was used to evaluate knee function.
In the novel method - Two suture anchors (TwinFix Ti 5.0 mm, Smith Nephew, London, UK) and Krackow-"8" suture were inserted in the proximal patellar fracture fragment. Three equal portions of proximal patellar fracture, with anchors placed in the decile points. Four equal portions distal to the fracture, with the Ultrabraid suture running through the corresponding point. The use of Tauting wire to replace fracture reduction. Ultrabraid sutures were sutured using "8" sutures over the patellar surface. The distal patellar fragment and the patellar tendon are sutured using Krakow technique sutures. Standard rehabilitation protocol was followed post operatively.
Results:
• The mean follow-up was similar for the AS and the K-wire groups (P > 0.05).
• The incision length of AS group was significantly smaller than that of K-wire group (P < 0.05). Mean incision length was 5.350 +/- 0.851 cm (range, 4 -7 cm) in the AS group and 11.722 +/-1.602 cm (range, 9 -14 cm) in the K-wire group (P < 0.05).
• The final follow-up on the range of motion of the knee: the average extension lag was similar in two groups (P > 0.05); flexion and flexion–extension angle was slightly better in the AS group than in the K-wire group.
• The Bostman patella fracture functional score of AS group were better than K-wire group at 3 and 6 months after operation. The sixth month after surgery, the score was 28.300 +/- 2.214 (range, 23 - 30) points in the AS group and 24.667 +/- 1.970 (range, 21 - 27) points in the K-wire group (P < 0.05).
• Four kinds of postoperative complications were seen in two groups – infection , non- union, implant failure & re-operation surgery.
• One patient (10%) in the AS group and two patients (11.1%) in the K-wire group had infections.
• Two (11.1%) cases of nonunion in group K and three patients (16.7%) required re-operation: one due to infection and two due to early implant failure.
• In the AS group, all distal pole fractures of the patella showed bony union, without loosening, falling, pulling out and nonunion of the fractures 6 months after operation.
The authors concluded that Anchor and Krackow-"8" suture fixation is an easily executed surgical procedure that can significantly reduce incision length and achieve better surgical outcomes than traditional procedures with regard to postoperative complications, knee function and without requiring a second operation. This technique is an effective operation method for the treatment of inferior patellar pole fractures.
Anchor and Krackow-"8" Suture for the Fixation of Distal Pole Fractures of the Patella: Comparison to Kirschner Wire.
Jia Xie1† , Yu Fu1,2† , Jun Li1 , Hao Yu1 , Yong Zhang1 , Juehua Jing.
DOI: 10.1111/os.13124
Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at
admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our
Terms of Use,
Privacy Policy, and
Advertisement Policy.
For further details, please review our
Full Disclaimer.

Recent News
Normal-Tension Glaucoma Closely Associated With Co...
- 10 October, 2022
Air Pollution Tied To Increased Risk Of Premature...
- 24 May, 2023
NEET PG 2024: NBE Opens Pre-Final Edit Window
- 30 May, 2024

Daily Newsletter
Get all the top stories from Blogs to keep track.
0 Comments
Post a comment
No comments yet. Be the first to comment!